DGS -

Dangerous goods
UN/CEFACT Revision 1997B Segment List

Function:To identify dangerous goods.
This segment also occurs in the following versions of this standard:
D93A, D94A, D94B, D95A, D95B, D96A, D96B, D97A, D97B, D98A, D98B, D99A, D99B, D00A, D00B, D01A, D01B, D01C, D02A, D02B, D03A, D03B, D04A, D04B

Pos Segment M/C Repeat Repr. Notes
010 8273 Dangerous goods regulations, coded C 1 an..3
020 C205 HAZARD CODE C 1
8351 Hazard code identification M an..7
8078 Hazard substance/item/page number C an..7
8092 Hazard code version number C an..10
030 C234 UNDG INFORMATION C 1
7124 UNDG number C n4
7088 Dangerous goods flashpoint C an..8
040 C223 DANGEROUS GOODS SHIPMENT FLASHPOINT C 1
7106 Shipment flashpoint C n3
6411 Measure unit qualifier C an..3
050 8339 Packing group, coded C 1 an..3
060 8364 EMS number C 1 an..6
070 8410 MFAG C 1 an..4
080 8126 Trem card number C 1 an..10
090 C235 HAZARD IDENTIFICATION PLACARD DETAILS C 1
8158 Hazard identification number, upper part C an..4
8186 Substance identification number, lower part C an4
100 C236 DANGEROUS GOODS LABEL C 1
8246 Dangerous goods label marking C an..4
8246 Dangerous goods label marking C an..4
8246 Dangerous goods label marking C an..4
110 8255 Packing instruction, coded C 1 an..3
120 8325 Category of means of transport, coded C 1 an..3
130 8211 Permission for transport, coded C 1 an..3

PosPosition
M/CMandatory or Conditional
Repr.Representation (Data or Content Type)

Segment DGS is used in the following messages:
BAPLIECOARRICODECOCOPARNCOPINOCOPRARCOREORCOSTCO
COSTORCUSCARDESADVDGRECAHANMOVIFCSUMIFTCCAIFTDGN
IFTFCCIFTIAGIFTMANIFTMBCIFTMBFIFTMBPIFTMCSIFTMIN
IFTSAIIFTSTAINVOICITRRPTMOVINSORDERSPRODATQUOTES
RETANNRETINSSAFHAZWASDIS

Change indicators
plus sign An addition.
asterisk Addition/substraction/change to a code entry for a particular data element.
hash or pound sign Changes to names.
vertical bar Changes to text for descriptions, notes and functions.
minus sign A deletion.
letter X Marked for deletion.

Return to EDIFACT D97B Segments page.